Application
Furnace Control Board
Control Voltage
24 VAC (18-30 VAC), 60 Hz
Line Voltage
208/230 VAC, 60 Hz
Pre-Purge
45 seconds
Trial for Ignition
5+2 seconds
Retry Period
Every 20 seconds for 15 minutes
Lockout
Manual reset
Post-Purge
45 seconds
LED Indicators
Red LED: Steady ON-normal operation
Flashing-fault codes Inputs
Spark – Gas Valve: GV – Combustion Motor: CM – Blower Motor: BM – Indoor Fan Motor: IFO
Brands Supported
Carrier
Item Shipping Weight (lbs.)
0.50
- Microprocessor-based
- Compatible with LP or Natural Gas
- Low Cost, Form, Fit and Functional Replacement Ignition Control
- Direct Spark Ignition Control Board
- Controls Combustion, Blower and Indoor Motors, Spark Igniter, Gas Valve
- Monitor Timing, Trial for Ignition, Flame Sensing and Lockout
- 100 Percent Lockout Safety Feature
- Status LED for Fault Codes to Aid in Troubleshooting