Application
Furnace Control Board
Input Voltage
18-30 VAC 50/60 Hz maximum
Ignitor
6.0 amp @ 120 VAC 50/60 Hz (resistive)
Inducer Relay
2.2 FLA–3.5 LRA @ 120 VAC
Blower Relay
14.5 FLA–25.0 LRA @ 120 VAC (2spd–H/C)
Gas Valve Relay
1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
Operating Temp Range
-40° to 176°F (-40° to 80°C)
Humidity Range
5 to 95% relative humidity (non-condensing)
Brands Supported
Goodman
Item Shipping Weight (lbs.)
0.50
- Controls the gas valve, inducer draft motor, circulating blower and hot surface ignitor
- Monitors system pressure and limit switches
- Microprocessor based precision
- Twinning compatible with another ICM2811 Control Board
- Diagnostic LEDs aid in testing and troubleshooting